Trouble Recovery
TIP:
The buzzer sounds only when the remote
control lever is placed in neutral.
1. Water separator-alert indicator
96
1
ZMU05441
ZMU01758
ZMU07012
1.
Stop the engine.
2.
Remove the top cowling.
3.
Remove the water detection switch lead
from the holder.
1
1. Holder
2. Water detection switch coupler
4.
Disconnect the water detection switch
coupler. NOTICE: Be careful not to get
any water on the water detection
switch coupler, otherwise a malfunc-
tion could occur.
5.
Remove the fuel filter from its holder.
2
ZMU08704
[ECM01951]