Napoleon HDX52NT-2 Instructions D'installation Et D'opération page 28

Masquer les pouces Voir aussi pour HDX52NT-2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

28
EN
65 7/8"
167.3cm
88"
223.5cm
ENCLOSURE
HEIGHT
* Within the appliance enclosure a 11" (279mm) clearance between the top of the vent pipe and combustible material is
required. All other clearance, including where the vent exits the enclosure are subject to 1 1/2" (38mm) to the sides and
bottom and 4 1/2" (114mm) to the top for horizontal and 1" (25mm) for vertical.
IMPORTANT: THE FIRESTOP ASSEMBLY PROVIDED MUST BE USED WHEN THE VENT PIPES PASS
THROUGH ANY WALL, FLOOR, OR CEILING.
W415-2180 / B / 08.29.18
STEEL STUD
FRAMING
NON-COMBUSTIBLE
MATERIAL
55 1/4"
140.3cm
41 7/8"
106.4cm
11"
279mm
4 1/2"
114mm
0" IF NON-COMBUSTIBLE
FINISHING MATERIAL
IS USED SUCH AS
BRICK AND STONE.
1 1/2"
38mm
FIRESTOP
ASSEMBLY
71 1/2"
181.6cm
2"
51mm