Table des Matières

Publicité

For new, refurbished and used cleaning equipment and supplies visit www.southeasternequipment.net
A - ENGLISH
MAINTENANCE
1)
Use only approved chemicals at the recommended mix ratios. All chemicals should be added through the feed system and NOT added
directly to the water in the solution tank to prevent possible damage to the pump, seals, or other components.
2)
For optimum performance, fl ush the Chemical Feed lines after every job by replacing the chemical containers with containers of clear water
and spraying through the gun until the fl uid stream is clear. See the Maintenance Schedule, below.
3)
The pump seals and/or valves in the high pressure pumps may need to be replaced after about 1000 hours of use, if the pump begins to
loose performance or to leak. The pressure regulator valve may need to be when a drop in the spraying pressure at the tool is apparent.
4)
If the 4", clear lid is removed from the top of the base (solution tank), you will need to apply a silicone sealant to the threads when you
reinstall the lid to seal for vacuum leaks.

MAINTENANCE SCHEDULE

ITEM
Flush chemical lines
Check/clean vac inlet fi lter
Clean solution fi lter
Check vacuum motor airways
Check pump for leaks
Check vacuum motor brushes*
* Have Advance check the carbon brushes once a year or after about 500 hours of operation.
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
MODEL
VACUUM MOTOR:
WATER LIFT:
AIR FLOW:
TANK CONSTRUCTION:
SOLUTION TANK CAPACITY:
RECOVERY TANK CAPACITY:
APPLICATION FLOW:
VAC & SOLUTION HOSE LENGTH:
POWER CORD:
HEIGHT:
WIDTH:
LENGTH:
WEIGHT
A-8
For new, refurbished and used cleaning equipment and supplies visit www.southeasternequipment.net
INSTRUCTIONS FOR USE
DAILY
WEEKLY
X
X
X
X
56380772
2 stage, 8 amp
97"
100 CFM
Rotationally molded polyethylene
20 gallon
12 gallon
200 psi
15 feet
25 feet
38.5 inches
21.25 inches
34 inches
85 LBS
ALL CLEANER - 56380890
QUARTELY
YEARLY
X
X
56381594
2 stage, 8 amp
97"
100 CFM
Rotationally molded polyethylene
20 gallon
12 gallon
400 psi
15 feet
25 feet
38.5 inches
21.25 inches
34 inches
85 LBS
revised 10/10
2/2010

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

All cleaner xp5638077256381594

Table des Matières