OILER TYPES USED ON OR WITH OUR TOOLS
Oiler to mount on the machine or connect in
the hose line
Setting the oiler: the adjustment screw item 2
is visible after removing the screw plug item 3.
Theoil supply is decreased by tightening the
screw, and by loosening the screw, more oil gets
into the machine. In most cases it is sufficient to
tighten or loosen the screw by ¼ or ½ of a turn.
When plugged, clean borehole (dia. 2 mm) with
wire.
Correct setting: when under pressure and with
the filler screw (item 4) open, the oil must bubble
slightly. The fillint lasts for approx. 8 operating
hours.
Line oiler
For stationary pneumatic machines and motors,
the lubrication is carried out by lined-up oilers for
horizontal or vertical installation.
Setting of oilers: Shut off air supply. Open plug
item 3. Loosen visible lock nut item 5 with a
socket wrench. Using a screw driver turn back
the tightened screw plug item 4 by ¼ to ½ of a
turn and then lock again. No oil is to get into the
borehole "a" when filling. Close plug item 3 and
open the air supply.
Correct setting: A piece of paper held for a short
time in front of the outlet must be coated with oil
without drops forming.
Transparent oiler
For installing in permanently equipped
workplaces (especially for type using service
units – see accessories list)
The transparent supply containers allow for good
checking as well as for good setting possibility
by means of a screw driver via a set screw with
visible dripping. (The set screw is above the
lateral thread connection – turning to the right for
less oil; turning to the left for more oil) The setting
(2 to 5 drops per m³/min air consumption) is to be
carried out when air is flowing through, i.e., when
the machine is running.