Melter Communications
Part 1024496_05
To restore pre‐upgrade melter settings
1. Place the melter into the configuration mode by simultaneously pressing
the Standby and Setup keys.
"COnF" appears in the right display.
2. Click Connect.
The Select COM Port dialog box appears.
3. Select the COM port you are using to connect to the melter, and then
click Ok.
The PC and melter establish communications and a picture of the melter
you selected appears in the device status area. The right side of the
status area indicates "CONNECTED".
4. Click Restore Pre‐Upgrade Settings.
The pre‐upgrade settings are restored and the melter returns to the scan
mode.
5. Click Exit to close the NCM.