7. Select the COM port you are using to connect to the melter, and then
click Ok.
The PC and melter establish communications and a picture of the melter
you selected appears in the device status area. The right side of the
status area indicates Connected.
8. Click Upgrade.
The Select Upgrade dialog box appears.
9. In the Available Upgrades list, select the firmware version you want to
upload to the melter, and then click Ok.
The upgrade warning message appears.
10. Click OK.
The Upgrade in Progress dialog box appears. The upgrade can take as
long as 12 minutes. When the upgrade is complete, the Success dialog
box appears and the melter restarts.
CAUTION! Once the uprade progress bar appears, do not interrupt the
upgrade process for any reason. Interrupting the upgrade can corrupt the
melter's firmware, which will require replacement of the IC chip
(IC service kit P/N 1018817).
11. Click OK.
The communications link between the melter and the PC is terminated.
12. Do one of the following:
S
To restore pre‐upgrade melter settings, go to To restore pre‐upgrade
melter settings on the next page.
S
To close the NCM, click Exit.
S
To restore melter settings other than the settings that were in use by
the melter before the upgrade, go to Saving and Restoring Melter
Settings earlier in this guide.
Melter Communications
Part 1024496_05
C‐9