Axis Communications P13-E Série Guide D'installation page 22

Caméras réseau
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Page 22
Note:
The I/O connector on the network camera is connected to the housing electronics at deliv-
ery and will trigger an input port event to indicate a fan or heater error when activated.
Please refer to the User's Manual, available on the CD provided with this product, or from
www.axis.com, for information on how to set up an event.
Function
Pin
GND
1
3.3 V DC
2
Power
Digital
3
Input
Digital
4
Output
AXIS P13-E Network Camera Series Installation Guide
Notes
Ground
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Connect to GND to activate, or leave floating
(unconnected) to deactivate.
Note: Connected to housing electronics at delivery.
Uses an open-drain NFET transistor with the source
connected to GND. If used with an external relay, a
diode must be connected in parallel with the load,
for protection against voltage transients.
Specifications
Max load = 50 mA
Min. input = -40 V DC
Max. input= +40 V DC
Max. load =100 mA
Max. voltage = + 40 V DC

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

P1343-eP1344-eP1346-eP1347-e

Table des Matières