Results

The integrated test run emission rate for test Run 1 was measured to be 1.46 g/hr with a
Higher Heating Values efficiency of 68.1% and a CO emission rate of 0.34 g/min. The
calculated first hour particulate emission rate was 3.11 g/hr. The United States Stove
Company Model 5520 Pellet-Fired Room Heater meets the 2020 PM emission standard
of ≤ 2.0 g/hr per CFR 40 part 60, §60.532 (b).
Detailed individual run data can be found in Appendix A submitted with this report.

Summary Table

Segments
Run
Date
Number
Setting
H
M
1
8/29/19
L
OA
Page | 7
EPA Application Table
Run
Heat
1st Hr
Time
Output
Emissions
(min)
(BTU/hr)
(g/hr)
BR
2.52
60
37379
0.91 120
11215
3.11
0.72 180
8506
1.08 360
14252
Project # 19-511
Integrated
CO
Overall CO
Total
Emissions
Emissions
(g/hr)
(g/min)
(g/min)
0.30
0.41
1.46
0.34
0.31
0.34
Model: 5520
Overall
Heating
Heating
Efficiency
Efficiency
(%HHV)
(%HHV)
76.7%
64.0%
68.1
61.0%
68.1%