Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ADVANCED CONFIGURATION

To go to advanced configuration, put both the rotary switches on position 9.
The door unit emits an acoustic signal and turns the signalling yellow led on.
At the end of operations, put again the door unit in stand-by mode, changing the position of one of the
rotary switches at least.
CONTROL CAMERAS (Only for 1083/78 and 1083/79)
If in a call module are present the control cameras, the function must be programmed.
1. Go to the advanced configuration, by setting both the rotary switches to position 9; the door unit emits
a beep to indicate the programming state and turns the yellow led on.
. Press the hall button (PA – CT) for the same times number as the present control cameras number. Each
time the button is pressed, the door unit emits the same beep number as the programmed cameras
number (5 max); by pressing again the button after 5 beeps, a long beep is emitted, to indicate that 0
cameras are connected (default).
3. Put again the rotary switches on the correct position to exit from the advanced configuration. The yellow
led turns off.
BUTTON CODES
Up to  buttons (in addition to the basic buttons) may be connected to the door unit using up to 4 button
expansion modules 1083/17.
By default the buttons are associate to the users from 0 to 3 of the column to which it belongs if the door
unit is configured as secondary unit.
If instead the door unit is configured as main unit, then the buttons are automatically associated to the
column 0, which simplifies the installation of main units in single column systems.
Instead, if the door unit is configured as main unit and several columns are present in the system, an
association must be created between the buttons and the users of the different column proceed as
follows:
Access advanced configuration by turning the two rotary switches to position 99 (the yellow LED will
light up).
Set the ID dip-switch to the code of the first column in the system (column 0 typically).
Press the button corresponding to user 0 of the selected column. All the subsequent buttons will be
automatically associated to the users of the column itself in sequence.
Repeat the operation on all the columns.
Reset the ID dip-switch in start position.
To quit advanced configuration, turn the two rotary switches to the door opening line and the guaranteed
conversation time setting positions. The yellow LED will go out.
Example:
System with 3 columns, the first with 4 users, the second with 6 users and the third with 8 users.
Access advanced configuration.
Set the ID dip-switch to 0.
Press the upper button of the door unit (first button).
Set the ID dip-switch to 1.
1
P5÷P8
P9÷P12
1083/17 (1)
P1÷P4
P13÷P16
INPUT
OUTPUT
P5÷P8
P9÷P12
1083/17 (4)
P1÷P4
P13÷P16
OUTPUT
DS1083-048

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1083/781083/79

Table des Matières