Operating conditions
US
Sanitary Specifications
Permissible flow pressure
Recommended flow pressure
Maximum difference in flow
pressure between HW + CW
Recommended difference in flow
pressure between HW + CW
Permissible Operating Temperatures
Cold water temperature
Recommended cold water temperature 59 °F
Hot water temperature
Recommended water temperature
Thermal disinfection (max.10:00)
Permissible Ambient Temperature 41 − 104 °F
Electrotechnical Data
Degree of protection
Potential equalization
(per eVALVE)
The customer has to provide a pressure
reducer in the main line downstream of the
water meter to comply with the noise levels
according to the noise class at a resting
pressure above 5 bar / 73 psi.
Recommended water hardness:
6 − 7 °dH / 107 − 125 ppm CaCO
7,5 − 8,8 °e / 10,7 − 12,5 °fH
Store somewhere dust-free and dry.
Maximum permissible relative humidity
(without condensation)
36 − 58 psi
44 psi
14,5 psi
≤ 7 psi
41 − 68 °F
131 − 149 °F
≤ 140 °F
≤ 167 °F
IP 55
4 mm² / AWG 11
/
3
95 %
Driftsvillkor
SE
Sanitetstekniska data
Tillåtet flödestryck
Rekommenderat flödestryck
Max. flödestryckdifferens
mellan VV + KV
Rekommenderat flödestryckdifferens
mellan VV + KV
Tillåtna drifttemperaturer
Kallvattentemperatur
Rekommenderad kallvattentemperatur 15 °C
Varmvattentemperatur
Rekommenderad
varmvattentemperatur
Termisk desinfektion (max.10:00)
Tillåten omgivningstemperatur
Elektrotekniska data
Kapslingsklass
Potentialutjämning
(per eVALVE)
En trycksänkare ska monterats in i huvudled-
ningen efter vattenmätaren för överensstäm-
melse med bullervärdena vid ett vilotryck över
5 bar.
Rekommenderad vattenhårdhet:
6 − 7 °dH / 107 − 125 ppm CaCO
7,5 − 8,8 °e / 10,7 − 12,5 °fH
Förvaras dammfritt och torrt.
Max. tillåten relativ luftfuktighet
(utan kondensbildning)
2,5 − 4 bar
3 bar
1 bar
≤ 0,5 bar
5 − 20 °C
55 − 65 °C
≤ 60 °C
≤ 75 °C
5 − 40 °C
IP 55
4 mm² / AWG 11
/
3
95 %
29