Planning notes
GB
General
Ceiling module
Ceiling construction with sufficient load carrying capacity for
the permanent attachment of the appliance (weight: 78,5 kg /
173 lbs. (US)).
M8 threaded bolts (minimum strength: 2,000 N) are required
to secure the ceiling module. Fasteners that are appropriate
for the particular ceiling have to be selected by a structural
engineer.
Wall components
The fasteners included in the scope of delivery are only
suitable for fixing in concrete.
Operating conditions
Permissible operating temperatures
Cold water temperature
Recommended cold water temperature
Hot water temperature
Recommended hot water temperature
Thermal disinfection (max. 10:00 mins.)
Must not be combined with continuous-flow heaters heaters.
Flow pressure
Permissible flow pressure
Permissible flow pressure with
optional accessory EMBRACE
Recommended flow pressure
Fit a speed-controlled pressure booster in the main pipe, if
necessary.
Water hardness
Recommended water hardness:
6 – 7 °dH / 107 – 125 ppm CaCO
If the water is harder, a water softener is to be installed in the
main cold water supply line.
Plumbing information
The pipework must be calculated in accordance with EN 806-3,
DIN 1988-300. To choose the perfect hot-water supply
– taking additional tapping points and simultaneous use into
consideration – an individual determination of requirements
(e.g. according to DIN 1988-200, DIN 4708-2, DIN 4753-7,
VDI 6003) is absolutely necessary. The simultaneous use of all
other outlet points must be considered (simultaneity).
Observe:
– Positioning of the connections
– Alignment of the QUEEN'S COLLAR
22
5 – 20 °C / 41 – 68 °F
15 °C / 59 °F
55 – 65 °C / 131 – 149 °F
≤ 60 °C / ≤ 140 °F
< 75 °C / 167 °F
250 – 400 kPa /
36 – 58 psi / 2.5 – 4 bar
300 – 400 kPa /
44 – 58 psi / 3 – 4 bar
300 kPa / 44 psi / 3 bar
 / 7.5 – 8.8 °e / 10.7 – 12.5 °fH
3
Drainage
ATT
Aquamoon
Drainage capacity / drain connection
value [DU value]
ATT
Aquamoon
with optional accessory
Drainage capacity / drain connection
value [DU value]
Recommended drain pipe size
To choose the perfect drain – taking the flow rate of the entire
installation into consideration – an individual determination of
requirements is necessary. (e.g. in accordance with
EN 12056-1/-2, DIN 1986-100).
Electrical information
Observe the regulations for protection zones according to
DIN VDE 0100, Part 701 (IEC 60364-7-701). Please conform to
national statutory regulations, where different.
The following electrical components must be installed outside
safety zones 0 – 2:
– fuse box,
– fragrance modules.
ATT
As AQUAMOON
, complete hand shower set and SMART
TOOLS control elements are operated by safety extra-low
voltage (12 V), they can be installed in safety zone 1.
Provided by the customer:
– Fuse box in accordance with planning requirements
– Safety cut-out
– Ground fault circuit interrupter
– Circuit-breaker switch
– 4 x Rail mounting TS 35
– Equipotential bonding rail
Observe:
– Do not roll up excess cable lengths .
– Shorten the excess cable lengths or fasten them in a
meandering pattern.
0.8 l/s / 0.2 gps
1.8 l/s / 0.5 gps
DN 75 / NPS 3"