Rogowski
IF96001 module RS485 communication
It makes available by RS485 communication the main data concerning carried out
measurements as well as configuration parameters (
In the models with built-in RS485 communication it allows to have an additional RS485
communication output.
Standard:
RS485 - 3 wires
Transmission:
asynchronous serial
Number of bit:
8
Stop bit:
1
Inquiry response time:
200ms
Max. number of network-connectable meters:
Max. distance from the master:
PROGR MM BLE P R METERS
N° address:
1...255
Transmission:
4.800 - 9.600 - 19.200 - 38.400 bit/s
Parity bit:
none - even - odd
Waiting min. time before answer:
Modbus message word format:
S 1000/273
RS 485
Rx / Tx
GND
+
3
4
5
22
For details, please see the communication protocol)
32 (up to 255 with RS485 repeaters)
1200m
3...99ms
Big Endian, Little Endian, Swap
USB
.
220Ω
A
B
GND
Tx /Rx