Dmx Linking; Signal Connection; Art-Net ™ Connection - Chauvet Professional MAVERICK STORM 1SPOT Guide De Référence Rapide

Masquer les pouces Voir aussi pour MAVERICK STORM 1SPOT:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
AC Plug
Connection
AC Live
AC Neutral
AC Ground
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
Replacing the Fuse
1.
Disconnect this product from power.
2.
Using a Phillips-head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove blown fuse and replace with a good fuse of the same type and rating.
4.
Screw the fuse holder cap back in place and reconnect power.

DMX Linking

The Maverick Storm 1 Spot will work with a DMX controller using a 5-pin DMX serial connection. A DMX Primer is
available from www.chauvetprofessional.com.
DMX Connection
The Maverick Storm 1 Spot uses a 5-pin DMX data connection for its DMX personalities: 33Ch and 26Ch. See the User
Manual for information about connecting and configuring the product for DMX operation.

Signal Connection

The Maverick Storm 1 Spot can link to controller software using an Ethernet connection. If using other Art-Net™ or sACN -
compatible products with the Maverick Storm 1 Spot, you can control each individually on a single network. See the User
Manual for information about how to connect and configure the product for these signals.
Art-Net
Connection
Art-Net™ is an Ethernet protocol that uses TCP/IP which transfers a large amount of DMX512 data using an Neutrik®
etherCON® RJ45 connection over a large network. An Art-Net™ protocol document is available from
www.chauvetprofessional.com. Chauvet Professional recommends using unicast Art-Net™ for best results.
Art-Net™ designed by and copyright Artistic Licence Holdings Ltd.
sACN Connection
Also known as ANSI E1.31, Streaming-ACN is an Ethernet protocol that uses the layering and formatting of Architecture
for Control Networks to transport DMX512 data over IP or any other ACN compatible network.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check the DMX controller's User Manual or with the manufacturer as not all DMX controllers
have this capability. The Maverick Storm 1 Spot supports RDM protocol that allows feedback to make changes to menu
map options. Download the User Manual from
Maverick Storm 1 Spot QRG Rev. 2
QUICK REFERENCE GUIDE
Wire (U.S.)
Black
White
Green/Yellow
www.chauvetprofessional.com
Wire (Europe)
Brown
Blue
Green/Yellow
for more details.
EN
Screw Color
Yellow/Brass
Silver
Green
2

Publicité

Table des Matières
loading

Table des Matières