Mild Acid Washing: Use only in severe cases where flushing and scraping will not remove the
majority of deposits. To acid wash, turn off power to Aqua Trol. Remove cell from piping. In a clean
plastic container, mix a 4:1 solution of water to muriatic acid (one gallon of water to one quart of
muriatic acid). ALWAYS POUR ACID INTO WATER - NEVER POUR WATER INTO ACID. Be sure to wear
rubber gloves and appropriate eye protection. The level of the solution in the container should just
reach the top of the cell so that the wire harness compartment is NOT submerged. It may be helpful
to coil the wiring before immersing the cell. The cell should soak for a few minutes and then rinse
with a high pressure garden hose. If any deposits are still visible, repeat soaking and rinsing. Replace
cell and inspect again periodically.
Winterizing
The Aqua Trol electrolytic cell and flow detection switch will be damaged by freezing water just as
your pool plumbing would. In areas of the country which experience severe or extended periods of
freezing temperatures, be sure to drain all water from the pump, filter, and supply and return lines
before any freezing conditions occur. The electronic control is capable of withstanding any winter
weather and should not be removed.

Spring Start-up

DO NOT turn the Aqua Trol on, until the pool water chemistry has been brought to the proper levels.
This information can be found on page 2.

Common Problems and Solutions

1.
"Power" LED not on
Check to make sure 120 VAC input power is connected to the Aqua Trol control. Verify input voltage
with a voltmeter. If there is input power, the fuse may have blown. The Aqua Trol is protected by a
20 amp mini ATO fuse located on the circuit board above the cell connector.
2.
"Generating" LED not on
The Aqua Trol only generates chlorine when the filter pump is running, the main switch is in the
"AUTO" or "SUPER CHLORINATE" position, and none of the red fault LEDs are illuminated.
3.
"Generating" LED flashing
The temperature of the pool water is too high or low to operate. You can override this by switching
the main switch to SUPER CHLORINATE. The Aqua Trol will run at maximum output for the remainder
of the current pump cycle or 24 hours, whichever comes first.
4.
"Check Salt" LED illuminated or flashing
Take a sample of your pool water to your local Authorized Aqua Rite Dealer Hayward and have the salt
level tested. No salt test is completely accurate and the test results may vary from the salt level on
the Aqua Trol display. If salt level is low, add salt according to chart on page 4 or 5.
12