8. Replacing temperature sensor

8.1 Components
NOTE: Start instruction with chapter 1 safety precautions
1. Remove screws.
2. Remove screws and lid.
3
3. Disconnect the old temp. sensor and then connect the
new sensor.
4. Assemble in reverse order.
5. Start machine and check that the temp. sensor is
working (/8. Selftest/Water temperature/....).
8
8.2 Tools
x 2
5mm
1
Water
Temp.
Sensor
J19
EN
T20
/8.Self test/...../Water Temperature/....