Electrical Installation

Electrical Requirements:
a three prong grounded outlet
120 V, 60 Hz, AC only
20 Amp electrical supply with a fuse or a circuit
breaker
This product must be connected to a supply circuit of the
proper voltage and frequency. Wire size must conform to
the requirements of the National Electric Code or the
prevailing local code for this rating. The power supply
cord and plug should be brought to a separate 20-amp
branch circuit single grounded outlet. The outlet box

Install Appliance

Removing the mounting plate

Note: To avoid possible damage to the work surface or
to the bottom of the appliance, cover the work surface.
Remove any remaining contents from the microwave
1.
oven cavity.
Remove the screws from the mounting plate.
2.
8

Power Requirements

The outlet must be properly grounded in accordance with
all applicable codes.
It can be installed inside the cabinet above the
appliance.
should be located inside the cabinet above the appliance
(see section Location Requirements). The outlet box and
supply circuit should be installed by a qualified
electrician and conform to the National Electrical Code or
the prevailing local code.
The voltage used must be the same as specified on this
microwave oven. Using a higher voltage is dangerous
and may result in a fire or oven damage. Using a lower
voltage will cause slow cooking. The dealer is not
responsible for any damages resulting from the use of
the oven with any voltage other than specified.
The mounting plate will be used as the rear wall
template and for mounting.