Installation - ESP15
5. Insert flapper valve into tee. Be sure
locator tab is in the notch of the tee
fitting (see Figure 2).
FLAPPER VALVE
TEE FITTING
LOCATOR
NOTCH
TAB
CLAMP
Figure 2
6. Slide clamp onto tee.
7. Insert pump into flapper valve, tilt
pump 30˚. When tilted, the side with
the power cord should be up (see
Figure 3). Tighten clamp around the
pump and flapper valve (see Figure 2).
INCORRECT
INCORRECT
Figure 3
Pump must be
tilted as shown in
Figure 3 to prevent air locking.
FLOAT
SWITCH
Figure 4
8. To install float switch for standby
pump, first slide bracket into slot on
top of tee. Secure bracket with screw
provided. Remove top hex nut from
switch and slide the cord up and out
of the way. Slip cord through slot in
bracket, pull threaded stud through
www.waynepumps.com
hole, and secure with nut. Make sure
(continued)
that float switch is above pump base
and that power wires do not interfere
with float switch or pump inlet.
Installation – ESP25
several hours. Before disabling your
main pump, have ready an appropriate
means of evacuating the sump.
1. Turn power to main pump off.
2. Pump must be installed using 1-1/4"
or 1-1/2" rigid PVC piping.
BACK-UP
SUMP PUMP

PUMP INSTALLATION

The ESP25 can be installed as a back-up
system with a separate dedicated discharge
line (Method 1), or tied into an existing
sump pump line (Method 2, Page 3).
follow this warning could result in fatal
electrical shock.
CORRECT
1. Verify that the existing AC pump
is in good working order. If the AC
pump is questionable, it is typically
recommended that the unit be
replaced with a 1/3 or 1/2 HP pump.
2. Remove any silt or accumulated
debris from the sump pit and
surrounding area.
30˚
Method 1 (Preferred)
1. Place the back-up pump on a solid,
level surface in the sump pit. Do
not place the pump on a loose or
sandy surface. Small stones or sand
may damage the pump resulting in
potential pump failure.
2. This pump has a 1-1/2 in. NPT
discharge. If a 1-1/4 in. discharge
pipe is desired, an adapter (sold
BACK-UP
separately) will be necessary.
SUMP
Smaller diameter piping will reduce
PUMP
pump flow, rate and performance.
INLET
3. Cut a 4 ft. section of 1-1/4 in. or 1-1/2
in. diameter rigid PVC pipe. Cement
1-1/4 in. pipe to a threaded fitting.
Cement 1-1/4 in. pipe into pipe
coupling. Attach 1-1/4 in. pipe section
1 IN. MIN.
to the ESP25 discharge adapter.
4. Screw PVC pipe onto pump discharge.
plastic fi ttings or check valves. Flex
hose is not recommended. Rigid PVC or
metal pipe is required for a permanent
installation.
5. Place the pump with the 4' section of
PVC pipe on a solid, level surface in
the sump pit on an elevated surface.
Installation of this
unit may take
Unplug the existing
AC pump. Failure to
Figure 5
6. Attach a rubber check valve (sold
NOTE: Check valves can be placed directly
in the pump discharge if desired. However,
for ease of disassembly, it is recommended
that check valves be placed above the
sump as shown in Figure 1, page 1.
The remainder of the discharge pipe
installation will vary depending on
individual circumstances. Using sound
plumbing practices, route the discharge
pipe to an exterior wall by the shortest
path. Keep turns to a minimum because
they reduce flow output of the pump.
The pipe that exits the building
structure should be sloped downward so
that water will not freeze in the pipe.
When installing the separate discharge
pipe, drill through the outside wall with
appropriate drilling equipment. Seal the
hole to prevent water from entering.
Method 2
If a separate, dedicated discharge is not
possible as in Method 1, the ESP25 pump
Be careful not to
can be tied in to the primary pump's
strip or cross thread
discharge pipe by installing a "Y" connector.
Two check valves will be required.
1. Locate the ESP25 on a solid, level
2
FLOOR
JOIST
RIGID
PVC PIPE
CHARGER
BATTERY
BOX
BACK-UP
PUMP
separately) to the top of the discharge
pipe. This will allow the pump or check
valve to be removed easily for servicing.
surface in the sump pit. Do not
place the pump on a loose or sandy
surface. Small stones or sand may
damage the pump resulting in
potential pump failure.
SLOPE
DOWN
PIPE
CHECK
VALVE
1-1/4"
OR
1-1/2"
PVC
PIPE