Transmitting A Daily Frame - ADEUNIS LoRaWAN AS-923 Pulse Guide Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LoRaWAN AS-923 Pulse - Guide utilisateur / User guide version V1.0.0
Eg:
Register
Value encoding
S320
Hexadecimal
S332
Decimal
S333
Decimal
S334
Decimal
S335
Decimal

2.2.5 Transmitting a Daily Frame

The product transmits every 24 hours a daily frame (0x30) according to the following diagram:
The transmission period of the daily frame is fixed (24 hours) and not configurable.
Value
Result
0x39
Channel A :
Channel B :
2
Scan period for A-channel tamper input is 2x10s = 20s
3
Tamper detection threshold for A-channel = 3 (positive scans of
B-channel tamper before triggering the tamper alarm)
2
Scan period for B-channel tamper input is 2x10s = 20s
3
Tamper detection threshold for B-channel = 3 (positive scans of
B-channel tamper before triggering the tamper alarm)
Product in standby
Period of
No
24h reached
?
Yes
Send frame 0x30
Initialization of min
and max flow rates
Initialization of alarm
states
Activated
Meter other than gas
Tamper input activated
Activated
Gas meter
Tamper input disabled
FR
EN
Page
65
of 99