golmar Vista Nexa Manuel D'installation page 123

Masquer les pouces Voir aussi pour Vista Nexa:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

122
V
ideo door entry system with
The installation diagram shows the connection of a video system with one or several door
panels for the same building.
If the system has one door panel only, override the wiring to the second door panel.
If the system has more than one door panel, wire the second panel as shown on the
diagram. In case of more than two door panels, wire them as the second is connected.
IMPORTANT:
D4L-R5R distributor may be used only 2 of the 4
these outputs are connected to one apartment with 2 monitors, (see page 126).
A
udio to be replaced
L
ock release
Independent (call line)
M
= Master.
= Slave.
S
FA-PLUS/C
rev. 938072
PRI
SEC
- -
230 110 0
Main
D4L-R5R distributor and
Wire correspondences
Golmar Vista PLUS
(3)
(5)
(10)
(P1)
Vista Nexa door panel
-
+
+
CV2
direct current door release.
distributed outputs
V
V
A/D
S
SW1
CN1
- -
+
+
CV1 +12
A/D
VI-
VI+
VO+
, when one of
2
Max. 0.25mm
VO-
To the next
door panel/s

Publicité

Table des Matières
loading

Table des Matières