WE and WY models
Model
WE10, WE13, WE16, WY10, WY13
Mode control
Turn the knob clockwise to High Heat for heating with highest fan
speed. Set to Med Heat for heating with medium fan speed. Turn to
Low Heat for heating with the lowest fan speed. Models designated
"WE" only use electric heating elements. Heat Pumps (WY models),
use the compressor for heating, au to mat i cal ly switching to electric
heating el e ments only when the outside temperature reaches 43°F.
Turn the knob counterclockwise to Fan Only for medium speed
without cooling or heating. Turn to High Cool for cooling with the
highest fan speed. Turn to Med Cool for cooling with medium fan
speed. Set to Low Cool for cooling with the lowest fan speed. Turn
the knob in either direction to Off to turn the unit completely off.
NOTE: The fan will cycle with the compressor or the heating element
and will not run constantly when in the heating mode.
920-007-12
Fan
Only
Low
Heat
Med
Heat
High
Heat
!
Allow 3 min. between restarts
Plug Type
NEMA No. 6-20P
Temperature control
This knob controls the thermostat – turn clockwise to set a cooler
temperature, coun ter clock wise to make it warmer.
Off
Low
Cool
Med
Cool
High
Cool
MAX
MAX
HEAT
COOL
Circuit Rating, Breaker
or Time Delay Fuse
250V-20 AMP
Figure 4