6.3

Alarm Cable Requirements

The terminal connector contains three Alarm In connections, two Alarm Out connections, and
1 relay.
Max. wire diameter
Alarm output relay
switching capability
Alarm Inputs
Alarm Outputs
6.4

Audio Cable Requirements

Wire Type
Distance
Gage
Shield
Center conductor
6.5

Making the Connections

All required connections are accessible by removing the rear end cap.
Notice!
Take care not to drop the end caps to prevent damage to the cap threads.
Notice!
Ensure to disconnect all cables from the interface board before removing the inner mounting
bracket assembly from the housing.
Refer to the following figure when making connections:
Figure 6.1: User Connections on User Interface Board
Bosch Security Systems
AWG 22-28 for both stranded and solid
Max voltage 30 VAC. Max 0.5 A continuous, 10 VA.
Three (3) non-supervised Programmable for "normally open" or
"normally closed"
Two (2) open collector/transistor outputs 32 VDC @ 150 ma
max.
1 dry contact relay
Shielded Coax (recommended)
Typically 10 m (33 ft), but depends on the signal level
Typically 22 AWG, but depends on the style of connector used
Bare copper braid: 95% coverage
Stranded bare copper
Installation Manual / Guide d'installation