Minimum Air Terminal Location - Napoleon Vector Serie Manuel D'installation

Masquer les pouces Voir aussi pour Vector Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.2
minimum air terminal location clearances
INSTALLATIONS
CANADA
U.S.A.
A
12" (30.5cm)
12" (30.5cm)
B
12" (30.5cm)
9" (229mm)
Δ
C
12" (30.5cm)*
9" (229mm) *
18"
18"
D
(45.7cm)**
(45.7cm)**
E
12" (30.5cm)**
12" (30.5cm)**
F
0" (0mm)
0" (0mm)
0" (0mm)***
0" (0mm)***
G
2" (51mm)***
2" (51mm)***
H
3'(0.9m)
3'(0.9m)****
I
3' (0.9m)
3' (0.9m)****
J
12" (30.5cm)
9" (229mm)
K
6' (1.8m)
3' (0.9m) †
L
7' (2.1m) ‡
7' (2.1m) ****
M
12" (30.5cm)††
12" (30.5cm)****
N
16" (40.6cm)
16" (40.6cm)
O
2' (0.6m)†*
2' (0.6m) †*
P
8' (2.4m)
8' (2.4m)
Q
3' (0.9m)
3' (0.9m)
R
6' (1.8m)
6' (1.8m)
S
12" (30.5cm)
12" (30.5cm)
Δ
The terminal shall not be located less than 6 feet under a window that opens on a horizontal plane in a structure with three walls and a roof.
*
Recommended to prevent condensation on windows and thermal breakage
**
It is recommended to use a heat shield and to maximize the distance to vinyl clad soffi ts.
***
The periscope requires a minimum 18 inches clearance from an inside corner.
****
This is a recommended distance. For additional requirements, check local codes.
3 feet above if within 10 feet horizontally.
A vent shall not terminate where it may cause hazardous frost or ice accumulations on adjacent property surfaces.
††
Permitted only if the veranda, porch, or deck is fully open on a minimum of two sides beneath the fl oor.
†*
Recommended to prevent recirculation of exhaust products. For additional requirements, check local codes.
††*
Permitted only if the balcony is fully open on a minimum of one side.
Clearance above grade, veranda porch, deck or balcony.
Clearance to windows or doors that open.
Clearance to permanently closed windows.
Vertical clearance to ventilated soffi ts located above the terminal within a horizontal distance of 2'
(0.6m) from the center line of the terminal.
Clearance to unventilated soffi t.
Clearance to an outside corner wall.
Clearance to an inside non-combustible corner wall or protruding non-combustible obstructions (chimney, etc.).
Clearance to an inside combustible corner wall or protruding combustible obstructions (vent chase, etc.).
Clearance to each side of the center line extended above the meter / regulator assembly to a maxi-
mum vertical distance of 15' (4.6m).
Clearance to a service regulator vent outlet.
Clearance to a non-mechanical air supply inlet to the building or a combustion air inlet to any other appliance.
Clearance to a mechanical air supply inlet.
Clearance above a paved sidewalk or paved driveway located on public property.
Clearance under a veranda, porch or deck.
Clearance above the roof.
Clearance from an adjacent wall including neighbouring buildings.
Roof must be non-combustible without openings.
See chart for wider wall dimensions.
See chart for deeper wall dimensions. The terminal shall not be installed on any wall that has an
opening between the terminal and the open side of the structure.
Clearance under a covered balcony
venting requirements
Covered balcony applications ††*
Q
R
Q
= 3 feet
R
MIN
= 2 x
Q
MAX
ACTUAL
(0.9m)
note:
In the absence of local codes and
gas supplier requirements, installation
must be done in accordance to the
national country requirements.
W415-1709 / A / 07.27.17
EN
S
P
G
R
≤ 15 feet
MAX
(4.6m)
9.1
17

Publicité

Chapitres

Table des Matières
loading

Table des Matières