2.4 Specification

pH Control Range:
• 7.0 to 8.0
ORP Control Range:
• 200 to 900
Input Power:
• 120 VAC 50/60 Hz auto-switching when supplied with
3-wire grounded power cord; GFCI source required
• 240 VAC 50/60 Hz capable
NOTE
The connection to the AquaPure ORP input as
shown in Figure 10 is only valid if the input power
to the C1900 is 120 VAC. If the input power to the
C1900 is 240 VAC, please contact technical support
department at 800.822.7933.
Controller Power:
• 1 amp, internally fused

Output Power:

• 120 VAC 50/60 Hz auto-switching when supplied with
3-wire grounded power cord; GFCI source required
• 240 VAC 50/60 Hz capable
NOTE
The connection to the AquaPure
shown in Figure 10 is only valid if the input power
to the C1900 is 120 VAC. If the input power to the
C1900 is 240 VAC, please contact technical support
department at 800.822.7933.
• 8A fuse for 120V, 4A fuse for 240V
Max load at 120V is 6.4A, 240V is 3.2A
• 3 HP (High power - line voltage) and 2 LP
(Low power - 24V) built-in relays
Operating Temp:
• 40 - 120°F
Sensors:
• pH: glass combination with 10' cable
• ORP: platinum combination with 10' cable
Inputs:
• AquaLink
RS485 Communications
®
ORP & pH sensors: BNC connector
Level detection: allows feeding, normally closed
Flow detection: allows feeding, normally closed
C1900 ORP and pH ChemLink™ Controller
Outputs:
ORP input as
®
|
Installation & Operation Manual
• Max load at 120V is 6.4A, 240V is 3.2A
• ORP Feeder - High Voltage
120 VAC 50/60 Hz (with 120V input)
240 VAC 50/60 Hz; (with 240V input)
8A on-board fuse for 120, 4A fuse for 240, normally
OFF
• ORP Feeder – Low Voltage, 24V
• pH Feeder – High Voltage,
120 VAC 50/60 Hz (with 120V input)
240 VAC 50/60 Hz; (with 240V input)
8A on-board fuse for 120, 4A fuse for 240, normally
OFF
• pH Feeder – Low Voltage, 24V
• RS485 for Communications with AquaLink RS
• Output connection to AquaPure ORP Control Input