2.2 Chuck
TE‑Y (SDS max) quick-change "click" chuck
2.3 Switches
Speed control switch for smooth starting
Combihammer function selector switch: Hammer drilling, chiseling, chisel adjustment (24 positions – depends on
version)
Selector for full or reduced (50%) power (depends on version)
Control switch locking mechanism which can be locked for chiseling (depends on version)
2.4 Grips
Vibration-absorbing, pivotable side handle
Vibration-absorbing grip
2.5 Protective devices
Mechanical safety clutch
Electronic restart interlock to prevent the power tool starting unintentionally after an interruption in the electric supply
(see section 9 "Troubleshooting").
Additional ATC "Active Torque Control" (TE 70‑ATC/AVR and TE 80‑ATC/AVR)
2.6 Lubrication
Gearing and hammering mechanism with separate lubrication chambers
2.7 Active Vibration Reduction
The tool is equipped with the "Active Vibration Reduction" (AVR) system, which significantly reduces vibration.
TE 80-ATC/AVR also has a handle damping system.
2.8 LED indicators
Service indicator LED (see section "Care and maintenance")
Reduced-power indicator (depends on version): (Please refer to the "Operation" section.)
2.9 Items supplied
1
Power tool
1
Side handle
1
Grease
1
Cleaning cloth
1
Operating instructions
1
Hilti toolbox
2.10 Using extension cords
Recommended minimum conductor cross section and max. cable lengths
Conductor cross section
Mains voltage 100V
Mains voltage 110-127 V
Mains voltage 220-240 V
2.11 Using a generator or transformer
This power tool may be powered by a generator or transformer when the following conditions are fulfilled: The unit
must provide a power output in watts of at least twice the value printed on the type identification plate on the power
tool. The operating voltage must remain within +5% and -15% of the rated voltage at all times, frequency must be in
the 50 – 60 Hz range and never above 65 Hz, and the unit must be equipped with automatic voltage regulation and
starting boost.
1.5 mm²
2.0 mm²
30 m
20 m
30 m
30 m
2.5 mm²
3.5 mm²
50 m
40 m
75 m