Power supply
612 ... .. 2 .. ....
612 ... .. 1 .. ....
Max. rated power
Circuit breaker
RCD
Protection rating
Protection class
Position of electrical / water connection
180
IG 1/2"
90
3
1/2"
Set the height of the toilet based on the position of the drain
according to the technical drawing of the toilet.

Pre-installation

DANGER
Risk of fatal electric shock
> Disconnect electrical components before the installation.
> Check that all components are de-energised.
> Prevent the power supply from being switched on accidentally
by third parties.
> Ensure that there is no damage to the power supply cable.
> Lay a permanent power supply line which must be on a
separate circuit.
• Please observe the position of the electrical connection.
• Leave at least 800 mm (31½") of the feed cable exposed.
> Install a circuit breaker.
• The device itself does not have an electrical leakage
protection function. The product must be installed in a
power circuit in which a residual current circuit breaker is
installed.
• Means for disconnection must be incorporated in the fixed
wiring in accordance with the wiring rules. In addition, it
must have a contact separation in all poles that provides full
disconnection under overvoltage category III conditions.
10
Laying a permanent power supply line
> Leave at least 800 mm (31 1/2") of the feed cable exposed.
220 – 240 V 50 - 60 Hz
100 – 120 V 50 - 60 Hz
(Taiwan models)
1080 W
I
 = 16 A
N
I
 = 30 mA
N
IP X4
1
7
1/8"
90
3
1/2"
Cold water
Water pressure
Water hardness
Pre-installation
> Install the water connection and water outlet in the specified
areas.
DANGER
Health risk and potential product damage!
> Supply the product with drinking water from the main water
system only.
> Do not connect any waste water, grey water, industrial water,
sea water or other untreated or semi-treated water.
Functional restrictions or product damage
NOTICE
due to limescale build-up
In regions with hard water, limescale build-up can impair the
performance of the product.
> Check the water quality in your region. Duravit recommends
the installation of a water softener with water hardness
≥ 14° dH (2.5 mmol/l).
11
Shutting off the water supply
NOTE
Avoiding water damage
> Shut off the water supply prior to the water installation.
13
Pushing the water hose through the ductwork into the
front-wall element
NOTE
Avoiding any malfunctions
> Only use the reinforced water hose from the installation kit.
57370_MAL_SeWa_Starck f_Installation kit #100731/19.12.1
DN 8 (¼")
0.07 – 0.75 MPa (10 - 109 psi)
max. 2.4 mmol/l
7