C) General features
The control board CTR58 contains a 2 channels radio receiver. The receiver can memorize up to 100 different codes of radio controls Fixed Code,
Rolling Code or working in environment Secret Key. The channel 1 of the radio receiver acts as Start, while the channel 2 acts as Pedestrian
Start. It is possible to reduce gate's speed next to stroke end (Slowing down function).
D) Working

1) Commands

Start (START)
Input N.O. to which to connect a button useful to ask gate's opening or closing. The command can be supplied also by radio control.
Pedestrian start (only by remote control)
Command useful to ask the partial opening of the gate (1/4 of the stroke). The command can be supplied only by remote control. The Pedestrian start
command is not affecting during start cycle until the end of closing step (closed gate). During a Pedestrian start, start is alway s working.

2) Safety devices

Photocell (FT)
Input N.C. to which to connect an optical barrier aimed to intercept and signal the passage of people and vehicles along the path covered by the gate
or next to it. The photocell is affecting only during closing step or in pause period. If an obstacle obscures the photocell when closing, it provokes the
stop and gate reverse after 1,5 sec. about. With fully open gate, an obstacle obscuring the photocell in the step previous to closing cycle start causes
the temporary stop of the gate. The blinker signals by fixed light the anomalous condition. As soon as the obstacle is removed closing step starts.
Photocell intervention during pause time recharges it extending the period before automatic closing.
Photostop (FTS)
Input N.C. to which to connect an optical barrier aimed to intercept and signal the passage of people and vehicles along the path covered by the gate
or next to it. If an obstacle obscures the photostop during motion or in the step previous to work cycle start, it causes the temporary stop of the gate.
The blinker signals with fixed light the anomalous condition. As soon as the obstacle is removed an opening cycle starts except when the gate is fully
open. In that case a closing cycle will start. Photo stop intervention during pause time recharges it extending the period before automatic closing.
Opening stroke end (FA)
Input N.C. to which to connect a device signalling when the gate has completed the opening stroke.
Closing stroke end (FC)
Input N.C. to which to connect a device signalling when the gate has completed the closing stroke.
Stop (STP)
Input N.C. to which to connect a device preventing work cycle start and, when supplied during motion, it provokes the immediate stop of the gate. This
condition remains until there is the command. After a stop command the following start command always sets in motion an opening cycle. A stop
command supplied during pause time interrupts work cycle.