PRACTICAL TIPS

DEPENDING ON MODEL
Model K 64750 AD
For both upper and lower zones the
cooling temperature could be set from 5
– 22°С. The lower zone temperature
could be set equal to or higher than
temperature in upper zone.
When the system malfunction occur
and alarm sound, press any key on the
control panel to cancel the sound.
When the temperature sensor failures
occur, error code displays. E1 for open
circuit; E2 for short circuit.
Model K 64800 AD
The left cooling temperature zone
could be set from 0 – 10 °C The right
cooling temperature zone could be set
from 5 – 20 °C.
When the system malfunction occur
and alarm sound, press any key on the
control panel to cancel the sound.
When the temperature sensor failures
occur, error code displays.
E1: open circuit of left zone tempreture
sensor;
E2: short circuit of left zone tempreture
sensor.
E3: open circuit of left defrost sensor ;
E4: short circuit of left defrost sensor.
E 5 : o p e n c i r c u i t o f r i g h t z o n e
tempreture sensor;
E 6 : s h o r t c i r c u i t o f r i g h t z o n e
tempreture sensor.
E7: open circuit of right defrost sensor;
E8: short circuit of right defrost sensor.