Troubleshooting
Fault
No performance or low
performance
Pump not running
No water is pumped, but
the pump is running
In the case of faults that are not listed in this table, or faults that you cannot rectify without assistance, please
contact our customer service department.

EC Declaration of Conformity

We hereby declare that this product, in the form marketed by us,
meets the requirements of the harmonised EC directives, the EC safety standards
and the product-specific standards.
Product
Aquatrolley
Serial number
G1001005
Type
A 300
470 625_b
Possible cause
Battery depleted
Sprinkler head clogged
Pump defective
Hose clogged or kinked
Battery depleted
Fuse defective
Cable not correctly connected to
battery
Water tank empty
Pump sucks in air
Manufacturer
AL-KO Geräte GmbH
Ichenhauser Str. 14
89359 KOETZ
GERMANY
EC directives
2006/95 CE
2004/108 CE
2000/14 CE
Conformity assessment
2000/14 EC, Annex V
Solution
Charge battery
Clean sprinkler head
Contact AL-KO Service Centre
Check spiral hose
Charge battery
Check fuse, exchange
Check cable
Switch off pump; fill tank
Vent pump: switch off pump, open lever on
sprinkler head, switch pump back on