CHAFFOTEAUX AQUANEXT PLUS 200 Instructions D'utilisation page 81

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Name
Parameter
P0
CODE
P1
RESET
P2
ANTI_B
P3
VOYAGE See chap. 7.4.
P4
PROG
P5
BOOST2 See chap. 7.4.
P6
SILENT
P7
HC-HP
P8
HE_SET Manage the operating modes.
P9
PV MODE
P10
T W PV
P11
T MAX
P12
T MIN
P13
T W HP
P14
TIME_W Number of accepted power supply times.
P15
HP HYST Compressor hysteresis temperature.
P16
T_A_HP Air temperature below which the compressor does not work.
P17
TANK_LT Product capacity (do not modify).
P18
SG MODE Operation with SG signal.
P19
ERRORS Faults history (read-only value).
P20
T AB
P2 parameter – Anti legionnaire's disease protection
If enabled, the water heater automatically performs the anti-Legionella protection
function. The water temperature must remain higher or equal to 55°C all day or higher
or equal to 60°C for at least 1 hour. These temperatures can cause burns, so we
recommend you use a thermostatic mixer. The anti-Legionella function is enabled via
this parameter; the temperature to be reached is settable via the P20 parameter and the
hysteresis via the P15 parameter. Suggesting to set the P20 parameter at 60°C and the
P15 parameter at 4°C. During the cycle of antilegionella will be displayed "ANTI_B"
alternately to the mode of operation, once the cycle is done the set temperature remains
the original one.
In the event that is enabled the two-tier rate signal HC-HP, the function will take place
during the economic tariff. To stop press "on/off".
P6 parameter - Silent
This function reduces the sound level (performance can vary from those declared). It can be enabled via
the P6 parameter on the installer's menu. When enabled, the image to the right appears on the display.
Parameter description
Code entering to access the installer menu. The number 222
appears on the display: turn the knob until reaching number
234 then press the knob. It will then be possible to access the
installer menu.
Re-set the factory parameters.
Anti-Legionella protection.
See chap. 7.4.
Set silent mode.
Operation with dual power supply.
Modify the operating modes based on the presence of the PV
signal.
It is the desired temperature when PV is in production.
Adjustment of the maximum temperature reachable
A value set higher allows you to take advantage of the larger
quantity of hot water.
Adjustment of the minimum temperature reachable
A value set lower allows you more operating economy if you
have economical hot water consumption.
It is the achievable temperature with only the heat pump.
Anti-Legionella set-point temperature
80
Range
Factory
settings
Min
Max
0
299
222
0
1
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
0
3
0
0
3
0
55
75
62
65
75
65
40
50
50
51
62
55
5
24
8
4
15
8
-7
20
-7
-
-
-
0
1
0
-
-
-
60
75
60