Les langues disponibles

Heating element
Heating element power
Max. water temperature with heating element
Max. current consumption
Power supply
Voltage / max. power consumption (
Frequency
Protection rating
Air side
Standard air flow rate (automatic modulating
control)
Available static pressure
Minimum volume of room of installation (
Minimum ceiling height of room of installation (
Min. temperature of room of installation
Max. temperature of room of installation
Minimum air temperature (w.b. at 90% r.h.) (
Maximum air temperature (w.b. at 90% r.h.) (
(A) Values obtained with external air temperature of 7°C and relative humidity at 87%, inlet water temperature of
10°C and set temperature of 55°C (according to the provisions set forth in EN 16147). Rigid Ø200 ducted
product, as per fig. 4.
(B) Values obtained with external air temperature of 7°C and relative humidity at 87%, inlet water temperature of
10°C and set temperature of 55°C (according to the provisions set forth in 2014/C 207/03 - transitional methods
of measurement and calculation). Rigid Ø200 ducted product, as per fig. 4.
(C) Values obtained from average results of three tests carried out with external air temperature of 7°C and relative
humidity at 87%, inlet water temperature of 10°C and temperature set according to the provisions set forth in
2014/C 207/03 - transitional methods of measurement and calculation and EN 12102). Rigid Ø200 ducted
product, as per fig. 4
(D) Value that ensures correct operation and eases maintenance if the product is not ducted. Correct operation of
the product is nevertheless ensured up to a minimum height of 2,090 m, as long as the accessory grilles are
used.
(E) Outside the operating temperature range of the heat pump, heating of the water is ensured by the integration.
Data collected from a significant number of products.
Additional energy data are shown on the Product Sheet (Attachment A) that is an integral part of this manual.
Products which do not have the label and data sheet required for boiler/solar power configurations pursuant to
regulation 812/2013 may not be used in such installations.
Heat pump water heater – GENERAL INFORMATION
W
ºC
A
A
)
V / W
Hz
3
m
/h
Pa
3
C
)
m
C
)
m
ºC
ºC
D
)
ºC
D
)
ºC
67
1500+1000
75
11,36
220-240 single-phase / 2500
50
IPX4
650
110
30
1,940
2,200
1
42
-7
42
2,200

Hide quick links: