Electrical Installation - Zodiac Jandy Pro VS FloPro Serie Manuel De Fonctionnement Et D'installation

Masquer les pouces Voir aussi pour Jandy Pro VS FloPro Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Jandy
Pro Series VS FloPro™ Series Variable-Speed Pump
®
NOTE
To prevent entrapment, the system must be built so
it cannot operate with the pump drawing water from only
one (1) main drain. At least two (2) main drains must be
connected to the pump when it is in operation. However, if
two (2) main drains run into a single suction line, the single
suction line may be equipped with a valve that will shut off
both main drains from the pump.
4.
The piping must be well supported and not forced
together where it will experience constant stress.
5.
Always use properly sized valves. Jandy Pro Series
Diverter Valves and Ball Valves typically have the
best flow capabilities.
6.
Use the fewest possible fittings especially 90 degree
elbows. Each additional fitting or length of pipe
increases resistance to flow which makes the pump
work harder.
NOTE
If more than ten (10) suction fittings are needed, the
pipe size must be increased.
7.
Every new installation must be pressure tested
according to local codes.
Replacement of Existing Pump
Jandy Pro Series VS FloPro pumps can easily replace
several other pumps: the Hayward
Hayward Super II™, Pentair
WhisperFlo
®
, Jandy Pro Series, PlusHP (PHP), Jandy
Pro Series MaxHP (MHP), Sta-Rite
Rite Dura-Glas II, Sta-Rite Dyna-Glas™, Sta-Rite
®
Max-E-Glas
, Sta-Rite Max-E-Pro
®
SuperMax
.
To replace the Pentair WhisperFlo, Jandy Pro Series
PHP, or Jandy Pro Series MHP, use the VS FloPro's
adjustable base. The VS FloPro base (and its spacers)
increase the total height of the pump and the height of
the suction side of the pump. See Table 2 and Figure 3.
NOTE
Adjustable base comes with FloPro models
VS-FHP1.0, VSFHP165JEP, VS-FHP2.0 and
VSFHP270JEP. If adjustable base is required for
VSFHP270AUT or VSFHP165AUT please see item 18 in
section 7.1 "Replacement Parts List and Exploded View."
Table 2.
VS FloPro Dimensions
Base Configuration
1. Pump without Base
2. Pump with Base
3. Pump with Base and
Spacers
4. Pump with Small + Large
Base
|
Installation & Operation Manual
®
Super Pump
®
,
®
®
SuperFlo
, Pentair
®
Dura-Glas, Sta-
®
, and Sta-Rite
Suction
Pump
Side
Height
Height
7 3/4"
12 3/4"
(197 mm)
(44 mm)
9"
14"
(229 mm)
(356 mm)
9 1/4"
14 1/4"
235 mm)
(362 mm)
10 7/8"
15 7/8"
276 mm)
(403 mm)
ENGLISH
Install Spacers into Small Base
1.
Using a hand cutter tool, cut the plastic bars
connecting the top and bottom sets of spacers, as
shown in Figure 4.
2.
Push the two (2) top spacers and two (2) bottom
spacers out of the base.
3.
Align the pins in the four (4) spacers with the holes
in the base and snap the spacers into place, as
shown in Figure 5.
Figure 4.
Cut Sets of Spacers Out of Base
Figure 5.
Snap Spacers into Place
3.2

Electrical Installation

Voltage Checks
The correct voltage, as specified on the pump data plate and
Table 3 on page 10 is necessary for proper performance and
long motor life. Incorrect voltage will decrease the pump's
ability to perform and could cause overheating, reduce the
motor life, and result in higher electric bills.
It is the responsibility of the electrical installer to provide
data plate operating voltage to the pump by ensuring
proper circuit sizes and wire sizes for this specific
application.
The National Electrical Code
requires all pool pump circuits be protected with a
Ground Fault Interrupter (GFCI). Therefore, it is also
the responsibility of the electrical installer to ensure that
the pump circuit is in compliance with this and all other
applicable requirements of the National Electrical Code
(NEC) and any other applicable installation codes.
Page 9
Cut
spacers
at X.
®
®
®
(NEC
, NFPA-70
)

Publicité

Table des Matières
loading