Table 3.
Recommended Wire Sizes for VS FloPro Pumps
RECOMMENDED MINIMUM WIRE SIZE FOR VS FLOPRO PUMPS*
Distance from Sub-panel
Model
VS-FHP1.0, VSFHP165AUT, VSFHP165JEP
VS-FHP2.0, VSFHP270AUT, VSFHP270JEP
*Assumes three (3) copper conductors in a buried conduit and 3% maximum voltage loss in branch circuit. All National Electrical Code
®
(NEC
) or the Canadian Electrical Code (CSA) and local codes must be followed. Table shows minimum wire size and branch fuse
recommendations for typical installation.
Failure to provide data plate voltage (within 10%)
during operation will cause the motor to overheat and
void the warranty.
Bonding and Grounding
1.
In addition to being properly grounded as
described in Electrical Wiring section, and
in accordance with the requirements of the
National Electrical Code (NEC), or in Canada the
Canadian Electrical Code (CEC), the pump motor
must be bonded to all metal parts of the swimming
pool, spa or hot tub structure and to all electrical
components and equipment associated with the
pool/spa water circulation system.
2.
The bonding must be accomplished by using a solid
copper conductor, No. 8 AWG or larger. In Canada
No. 6 AWG or larger must be used. Bond the motor
using the external bonding lug provided on the
motor frame.
WARNING
Always disconnect the power source before working
on a motor or its connected load.
WARNING
Make sure that the control switch, time clock, or
control system is installed in an accessible location,
so that in the event of an equipment failure or a loose
plumbing fitting, the equipment can be turned off. This
location must not be in the same area as the pool
pump, filter, and other equipment.
The pump must be permanently connected to a
dedicated electrical circuit. No other equipment,
lights, appliances, or outlets may be connected to the
pump circuit, with the exception of devices that may
be required to operate simultaneously with the pump,
such as a chlorinating device or heater.
Jandy
Pro Series VS FloPro™ Series Variable-Speed Pump
®
Inverse - Time Circuit Breaker or Branch Fuse AMPS
CAUTION
CAUTION
Class: CC, G, H, J, K, RK, or T
230 VAC
15A
20A
Breaker Panel
GROUND
GFCI
Figure 6.
Bonding the Motor
Electrical Wiring
1.
The pump motor must be securely and adequately
grounded using the green screw provided. Ground
before attempting to connect to an electrical power
supply. Do not ground to a gas supply line.
2.
Wire size must be adequate to minimize voltage
drop during the start-up and operation of the pump.
See Table 3 for suggested wire sizes.
3.
Insulate all connections carefully to prevent
grounding or short-circuits. Sharp edges on
terminals require extra protection. For safety, and to
prevent entry of contaminants, reinstall all conduit
and terminal box covers. Do not force connections
into the conduit box.
NOTE
When power alone is supplied to this pump, it will not
operate. It requires a digital command sent to it by either
a variable speed controller (JEP-R), an AquaLink
controller, an AquaLink Pool Digital Assistant (PDA), or
an AquaLink Z4™, to operate at a chosen speed.
|
Installation & Operation Manual
0-150 Feet
(0-45 metres)
Gauge of Wire
Voltage
230 VAC
12
10
®
Bonding Lug
Terminal Block
Variable-Speed
Pump (230 VAC)
®
RS