Before you store the air compressor,
make sure you do the following:
1.
Review the "Maintenance" section
on the preceding pages and per-
form scheduled maintenance as
necessary.
2.
Set the On/Off switch to OFF (O)
and unplug unit.
3.
Turn the regulator counterclock-
wise and set the outlet pressure
to zero.
4.
Remove the air tool or accessory.
5.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately 20
psi. Release safety valve ring.
6.
Drain water from air tank by open-
ing drain valve on bottom of tank.
REPLACEMENT PARTS
Use only identical replacement parts. For a parts list or to order parts, visit our website at
servicenet.porter-cable.com. You can also order parts from your nearest factory-owned
branch, or by calling our Customer Care Center at 1-888-848-5175 to receive personal-
ized support from highly-trained technicians.
FREE WARNING LABEL REPLACEMENT
If your warning labels become illegible or are missing, call (888)-848-5175 for a free
replacement.
SERVICE AND REPAIRS
All quality tools will eventually require servicing and/or replacement of parts. For informa-
tion about Porter-Cable, its factory-owned branches, or an Authorized Warranty Service
Center, visit our website at www.porter-cable. com or call our Customer Care Center
(888)-848-5175.
at
defective material and workmanship. We cannot guarantee repairs made or attempted by
others.
You can also write to us for information at PORTER-CABLE, 4825 Highway 45 North,
Jackson, Tennessee 38305 - Attention: Product Service. Be sure to include all of the infor-
mation shown on the nameplate of your tool (model number, type, serial number, etc.).
A complete line of accessories is available from your Porter-Cable•Delta Supplier, Porter-
Cable•Delta Factory Service Centers, and Porter-Cable Authorized Service Stations. Please
visit our Web Site www.porter-cable. com for a catalog or for the name of your nearest
supplier.
could be hazardous. For safest operation, only Porter-Cable•Delta recommended
accessories should be used with this product.
A15414

STORAGE

SERVICE

All repairs made by our service centers are fully guaranteed against

ACCESSORIES

Since accessories other than those offered by Porter-Cable•Delta
have not been tested with this product, use of such accessories
dense in the air tank. If not drained,
water will corrode and weaken the
air tank causing a risk of air tank
rupture.
7.
After the water has been drained,
close drain valve by turning
clockwise.
NOTE: If drain valve is plugged,
release all air pressure. The valve can
then be removed, cleaned, then rein-
stalled.
8.
Wrap electrical cord onto the cord
wrap.
9.
Protect the air hose from damage
(such as being stepped on or run
over).
10. Store the air compressor in a
clean and dry location.