Supply Module Terminal Assignment Hand Scanner Bcs 03 Ex ( Type 17-2111-0500 ); Interbus Module Terminal Assignment ( Type 17-2111-0600 ); Supply Module Terminal Assignment Hand Held Scanner Bcs 302; Ex ( Type 17-2111-0700 ) - Bartec BAT VGA pro Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operator´s manual for BAT VGA pro
Version 1.1
2.2.4
Supply module terminal assignment hand scanner BCS 03
Pin
Signal
1
PA
2
GND
3
TxD
4
+U
B
5
GND
2.2.5

INTERBUS module terminal assignment ( Type 17-2111-0600 )

Pin
Signal
DO1
1
2
DO1
3
DI1
4
DI1
5
GND1
6
SHD1
7
DO2
8
DO2
9
DI2
10
DI2
11
GND2
12
SHD2
13
RBST
14
+5 V
2.2.6

Supply module terminal assignment hand held scanner BCS 302

Pin
Signal
1
PA
2
GND
3
TxD
4
+U
B
5
GND
E_BMS00680_Rev7.doc • Operator´s manual for BAT VGA pro • Revision 7 / Status: 29. January 2004 • Technical data subject to change
Description
Grounding
Signal ground (internal bridge to supply ground existing)
Data input RS232 signal
Supply voltage BCS 03
Supply ground (internal bridge to signal ground existing)
Description
INTERBUS transmission cable input
INTERBUS transmission cable input
INTERBUS receiving cable input
INTERBUS receiving cable input
INTERBUS common ground input
INTERBUS shielding input
INTERBUS transmission cable output
INTERBUS transmission cable output
INTERBUS receiving cable output
INTERBUS receiving cable output
INTERBUS common ground output
INTERBUS shielding output
Bridge for activating the
INTERBUS-output
Description
Grounding
Signal ground (internal bridge to supply ground existing)
Data input RS232 signal
Supply voltage BCS 03
ex
/ BCS 302
Supply ground (internal bridge to signal ground existing)
ex
( Type 17-2111-0500 )
ex
( Type 17-2111-0700 )
ex