Safety Features - Base Camp F235896 Instructions Pour L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SAFETY FEATURES FOR YOUR AqUACUBE®
IMPORTANT –
This appliance is designed to
be used with a source water temperature of 68ºF or
below, if the temperature of the outlet water exceeds 113º
-122ºF the burners will shut off and will only relight once
the outlet water temperature falls below 113ºF.
This appliance is designed to raise the outlet water
temperature by a maximum of 45º F (Shower head) and
35º F (tap) above the source water temperature and can
be adjusted by the gas control and flow adjuster. In the
event that the temperature lift is insufficient, simply run
water through the appliance once returning the heated
water to the source water reservoir. Run again through
the appliance until the desired temperature is reached.

SAFETY FEATURES

This appliance is equipped with the following safety
features:
• o ver temperature Sensor – the appliance will not
allow the burner to remain in operation once the outlet
water temperature reaches 113-122ºF, the burner will
automatically relight once the outlet temperature falls
below 113ºF.
• water Flow Sensor – water must be flowing through
the system to allow the burner to ignite. In the case
that the water supply is restricted or ceases, ie. the
Flow Switch is in the "off" position, the burner will be
extinguished and will not relight until the water flow
recommences.
• tilt Switch – in the event that the appliance is moved
during operation or is being operated on an unstable
or non-solid surface the appliance will shut down and
must be switched off until a
suitable surface is located.