TROUBLESHOOTING AND ERROR CODES

PrOBLEm
CAUSE
Check that appliance is switched on
Check sufficient water is available
Water will
Check that the pump is connected to the appliance
not flow from
Check that adequate DC power is available
shower head
Check DC fuse in cigarette lighter fitting
Check that the shower flow water regulator is in the open position
Check that gas cylinder is turned on and that there is gas in cylinder
Burner will
Check that the water is flowing from shower head
not light
Check that the water is not over temperature
Check gas control
Water is not
Check source water temperature
hot enough
Cycle the water through the system back in to the source reservoir then through the appliance
again
ERROR CODES
The appliance is fitted with a number of operational &
safety features that can be identified by the following
error codes in the event that the unit will not operate:
e3: No Flame / Burner not lit
e6: over Temp Shut off
e7: O utlet Water Temp Exceed 118ºF
e8: Tilt Switch Activated
This unit carries a 12 MONTH WARRANTY.
For repair service call 800.251.0001. If product must be returned to Basecamp service, attach to
the product a tag stating your name, address daytime phone number and an email and a
description of your issue. DO NOT send propane cylinder. Carefully package the product and
send either by courier or insured mail with shipping and insurance to us Basecamp Service:
Basecamp Service, 4560 West 160th Street, Cleveland ,OH 44135
If not completely satisfied with the performance of your product,
For products purchased in the United States:
800.251.0001
please call 800.251.0001