8.4 Electrical connection
• Ground the appliance according to
safety precautions.
• Make sure that the rated voltage and
type of power on the rating plate
agree with the voltage and the power
of the local power supply.
• This appliance is supplied with a mains
cable.
• Any electrical component must be in-
stalled or replaced by the Service
Force Centre technician or qualified
service personnel.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is an access to
the mains plug after installation.
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• The appliance must not be connected
with an extansion cable, an adapter or
a multiple connection (risk of fire).
Check that the ground connection is
in conformity with the standard and
regulations force.
8.6 Assembly
R 5mm
55mm
min.
650mm
min.
450mm
+1
490
mm
+1
340
mm
• The power cable must be placed in
such a way that it does not touch any
hot part.
• Connect the appliance to the mains
with a device that lets to disconnect
the appliance from the mains at all
poles with a contact opening width of
minimum 3 mm, eg. automatic line
protecting cut-out, earth leakage trips
or fuse.
• None of a parts of the connection ca-
ble can not get a temperature 90°C.
8.5 Replacement of the
connection cable
In order to replace the connection cable
speak your local Service Force Centre!
To replace the connection cable use on-
ly H05BB-F Tmax 90°C (or higher) type.
Make sure that the cable section is appli-
cable to the power and the working tem-
perature. The yellow/green earth wire
must be approximately 2 cm longer than
all phase wires.