S+S Regeltechnik AERASGARD RCO2 Mode D'emploi

S+S Regeltechnik AERASGARD RCO2 Mode D'emploi

Masquer les pouces Voir aussi pour AERASGARD RCO2:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

D G F r
6002-8100-2011-000 28100-2014 01 ⁄ 2014
RCO
® 
AERASGARD
D
Bedienungs- und Montageanleitung
Raum- CO
- Fühler bzw. Messumformer,
2
selbstkalibrierend, mit Mehrbereichsumschaltung und
aktivem Ausgang
G
Operating Instructions, Mounting & Installation
Room CO
sensors respectively measuring transducers,
2
self-calibrating, with multi-range switching and
active output
F
Notice d'instruction
Sonde (transmetteur) de CO
auto-calibrante, avec commutation multi-gamme et
sortie active
r
Руководство по монтажу и обслуживанию
Датчик ⁄ измерительный преобразователь
содержания CO
для внутренних помещений,
2
самокалибрующийся, с переключением диапазонов
измерения и активным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
2
d'ambiance,
2
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
RCO
2
RCO
2
mit Display
with display
avec écran
с дисплеем
RCO
2
(Edelstahl)
(stainless steel)
(acier inox)
(высококаче-
ственной стали)

Publicité

Table des Matières
loading

Sommaire des Matières pour S+S Regeltechnik AERASGARD RCO2

  • Page 1 самокалибрующийся, с переключением диапазонов измерения и активным выходом (Edelstahl) (stainless steel) (acier inox) (высококаче- ственной стали) S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben. PIRNAER STRASSE 20 Congratulations! 90411 NÜRNBERG ⁄ GERMANY You have bought a German quality product.
  • Page 2 D G F r ®  AERASGARD Maßzeichnung Gehäuse Frija II Dimensional drawing Enclosure Frija II boîtier Frija II Plan coté Габаритный чертеж Корпус Frija II Maßzeichnung Gehäuse Edelstahl Dimensional drawing Enclosure stainless steel Plan coté boîtier acier inox Габаритный чертеж Корпус...
  • Page 3: Technische Daten

    AERASGARD ® ® Der wartungsfreie mikroprozessorgesteuerte AERASGARD dient zur Erfas- Schaltbild sung des CO - Gehaltes der Luft. Er ist wahlweise mit ⁄ ohne Display erhältlich. Die Messsignale werden in Standardsignale von 0 - 10 V umgewandelt. Optional kann der UB+ 24V AC/DC - Messumformer mit Schaltausgang geliefert werden.
  • Page 4: Montage Und Installation

    Montage und Installation ACHTUNG !  - Gehalt Die minimale CO - Konzentration von Außenluft beträgt in begrünten, (Messbereich einstellbar) industrie armen Gegenden ca. 350 ppm (Ausgangs spannung = 1,75  V). Der 0 … 2000 ppm (default) Gasaustausch im Sensorelement erfolgt durch Diffusion. Je nach Konzen- trationsänderung und Strömungs geschwindigkeit der Luft in Sensorum- 0 …...
  • Page 5 Wichtige Hinweise – Dieses Gerät darf nur in nicht kondensierender Luft ohne Über- oder Unterdruck am Sensorelement eingesetzt werden. – Der Spannungsausgang ist kurzschlussfest. – Dass Anlegen einer Überspannung zerstört das Gerät. – Bei Verunreinigungen empfehlen wir eine werksseitige Reinigung und Neukalibrierung. –...
  • Page 6: Technical Data

    AERASGARD ® ® The maintenance-free microprocessor-controlled AERASGARD is used to Connecting diagram detect the CO content in air. This sensor is optionally available with or without display. The measurement signals from the CO transmitter are converted into UB+ 24V AC/DC standard signals of 0 -10 V.
  • Page 7 Mounting and Installation ATTENTION! content The minimum CO concentration of outdoor air amounts to ca. 350 ppm (measuring range selectable) (output voltage = 1.75 V) in leafy, hardly industrialized areas. A sensor 0 … 2000 ppm (default) self-test is initiated by above-atmospheric or below-atmospheric pres- sure or by exposure of the sensor to more than 5000 ppm CO .
  • Page 8 General notes – This device may only be used in non-precipitating air without above-atmospheric or below-atmospheric pressure at the sensor element. – The voltage output is short-circuit proof. – Applying overvoltage will destroy the device. – In case of pollution, we recommend cleaning and recalibration in the factory. –...
  • Page 9: Caractéristiques Techniques

    AERASGARD ® ® Les sondes AERASGARD , sondes auto-calibrantes commandées par micro- Schéma de raccordement processeur, servent à la mesure de la teneur en CO de l’air sur une plage de 0 ppm à 2000 ppm de CO . Le capteur de CO est disponible au choix avec ⁄...
  • Page 10: Montage Et Installation

    Montage et installation ATTENTION ! Teneur en CO La teneur minimale en CO de l’air extérieur dans des régions vertes (plage de mesure réglable) à faible degré d’industrialisation est de l’ordre de 350 ppm (tension de 0 … 2000 ppm (par défaut) sortie = 1,75 V).
  • Page 11: Généralités

    Généralités – Cet appareil ne doit être utilisé que dans un air sans risque de condensation, sans risque de surpression ou dépression sur l’élément sensible. – La sortie en tension est isolée de la masse. – L’application d’une surtension causera la destruction de l’appareil. –...
  • Page 12: Технические Данные

    AERASGARD ® Не нуждающийся в техническом обслуживании, управляемый микропроцессором Схема подключения датчик AERASGARD ® служит для измерения содержания углекислого газа в воздухе. Поставляется на выбор с дисплеем или без него. Сигналы измерения UB+ 24V AC/DC преобразуются в стандартные сигналы 0 - 10 В. Опционально поставляется изме- UB- 24V AC/DC рительный...
  • Page 13: Монтаж И Подключение

    Монтаж и подключение ВНИМАНИЕ! Содержание CO Минимальная концентрация CO в наружном воздухе в озелененных (настраиваемый диапазон измерения) районах с малым количеством промышленных объектов составляет 0 … 2000 ppм (стандартный диапазон) прибл. 350 ppm (выходное напряжение 1,75 В). Пониженное ⁄ повышен- ное...
  • Page 14: Напряжение Питания

    Указания к продуктам – Данный прибор допускается применять только в воздухе без конденсата и вредных веществ, при отсутствии пониженного или повышенного давления вблизи чувствительного элемента. – Выход напряжения защищен от короткого замыкания. – Приложение завышенного напряжения к выходу напряжения выводит прибор из строя. –...
  • Page 15 Reprints, in part or in total, are only permitted with the approval of S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r ®  AERASGARD...

Table des Matières