Always handle the clip leads and the cables by
their insulation, never directly by the exposed
metal of the test clips. Use only the insulated clips
provided to connect to any wire or cable.
To prevent unreliable test results, use only the test
leads supplied with the tester or supplied by Fluke
Networks as accessories for the tester.
Do not use test leads if they are damaged. Examine
the test leads for exposed metal and damage to
the insulation. Make sure the wear indicator on the
cords does not show. The wear indicator is white
for the two cords that come out of the test clips
and black for the single cord that comes out of the
Y-shaped splitter. Verify the continuity of the test
leads.
To prevent unreliable test results, replace the
battery as soon as L.LLL shows on the display.
Before you remove the battery door, disconnect
the test leads from the tester.
Use only four AA batteries, correctly installed, to
supply power to the tester.
Do not use the tester without the battery door
installed.
If this product is used in a manner not specified by
the manufacturer, the protection provided by the
product may be impaired.
W
Use the TS100 only on dry (non working)
circuits. If you connect the TS100 to an
operating ADSL or hi-cap circuit, it can cause
the service to be dropped.
Legal requirements may exist regarding
permission to connect equipment to a
Telecom network operated by a public
network operator.
Caution

Design Features

Design features of the TS100 Cable Fault Finder
include:
Easy to use
Tests all common cable pairs
Provides low cost protection against lost time due
to cable and connector problems
Single button operation
Up to 3000 feet (900 meters), dependent on cable
type
Accurate to ±2 feet (±1 meter) for short cables
Accurate to ±5 feet (±2 meters) for cables from
10 feet (3 meters) to 200 feet (60 meters) and ±3%
and ±5 feet (±2 meters) for cables longer than
200 feet (60 meters)
Bright 0.4 inch (1.016 centimeters) LED display
Up to 4 readings per second
Audible indication of shorted wires and external
voltage greater than 15 VAC
Automatic adjustments
Tone injection with the PowerTone™ positive
identification system
Input protected to 250 VAC
Components protected against damage from
moisture
Fifty hour battery life, intelligent auto-off
Low battery indicator
Uses 4 AA batteries (included)
High strength plastic (ABS) housing
Design Features
3