Technical Data For Electrical Connection - Inoxtrend GCA 304 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
EN
1.5 POSITIONING OF THE OVEN
The place where the oven will be installed must comply the following requirements:
Be protected from atmospheric agents and have an adequate air circulation;
Comply with regulations concerning safety at work;
Have a room temperature between 5 °C and 35 °C with a humidification not higher than 70%.
Place the oven and proceed with levelling using adjustable feet.
Keep a suitable distance at the back, in order the label of equipotential clamp is easy to see when the oven has
been installed.
The same clamp must be easy to access to install equipotential cable after the oven has been installed in compli-
ance with our instructions.
Install the appliance in a position that allows access to the right side for installation, maintenance and technical
assistance.

1.6 TECHNICAL DATA FOR ELECTRICAL CONNECTION

Model
4 x 433x333
230V+ 1 ~ 50/60 Hz
4 x 433x333
reduced
230V+ 1 ~ 50/60 Hz
power
4 x 433x333
grill
230V+ 1 ~ 50/60 Hz
4 x 2/3 GN
230V+ 1 ~ 50/60 Hz
4 x 2/3 GN
reduced
230V+ 1 ~ 50/60 Hz
power
4 x 2/3 GN
grill
230V+ 1 ~ 50/60 Hz
4 x 60X40
230V+ 1 ~ 50/60 Hz
4 x 60X40
grill
230V+ 1 ~ 50/60 Hz
4 x 60X4
increased
230V+ 1 ~ 50/60 Hz
power
The ovens are supplied equipped with an electric power cable.
4 x 2/3 GN - 4 x 460x340 - 4 x 60x40 / ANALOGIC
Power loading
and voltage
3.3 kW
2.8 kW
3.5 kW
3.3 kW
2.8 kW
3.5 kW
3.3 kW
3.5 kW
4.8 kW
no. and motor
Heating
power
power
2 x 100 W
3.2 kW
2 x 100 W
2.6 kW
2 x 100 W
2.8 kW
2 x 100 W
3.2 kW
2 x 100 W
2.6 kW
2 x 100 W
2.8 kW
2 x 100 W
3.2 kW
2 x 100 W
2.8 kW
2 x 100 W
4.6 kW
16
Grill
Absorbed
power
current
--
5.5 A
--
4.7 A
0.7 kW
5.8 A
--
5.5 A
--
4.7 A
0.7 kW
5.8 A
--
5.5 A
0.7 kW
5.8 A
--
8.0 A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gca 404Gca 604Gua 304Gua 404Gua 604

Table des Matières