Fault Finding And Corrective Action - Graf AQUA-CENTER SILENTIO 15/4 Notice D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Working on the electrical system may only be carried out by a professional electrician!
Fault
Pump does not run
Pump does not draw
Pump does not switch off
Pump discharge rate
insufficient
Thermal circuit breaker
shuts down the pump
info@graf-online.de
www.graf-online.de

7. Fault finding and corrective action

Cause
- No electrical power
- Pump impeller jammed
- Suction valve is not in the water
- Pump impeller without water
- Air in the suction pipe
- Blocked suction basket
- Max. Suction height or length of
suction pipe has been exceeded
- Possibly an outlet is open (water
left running)
- Pressure hose or outlet is
leaking
- Suction height too high
- Blocked suction basket
- Dirt in system equipment
- Pump head height too high
- Overloading due to dirt in the
motor housing
www.graf.info
page 22 of 44
Corrective action
- Plug into or check the electrical
supply
- Professional pump overhaul or
service and cleaning
- Suction valve should be
brought below the waters
surface
- Fill the system with water
- Air bleed the system and check
for leaks
- Clean the suction baske
- Check the suction height or
change the pump position or use
a submersible pump
- Close the outlet
- Repair the leaking pressure
hose or outlet
- Check the suction height or
change the pump position or use
a submersible pump
- Clean the suction basket
- Clean all system components
and overhaul or service the
pump from professionals
- Check the pump head height , or
change the pump position or use
a larger pump
- Professional pump overhaul or
service and cleaning
- Prevent the drawing in of dirt
and foreign objects