Western Co WRM30+ Manuel De L'utilisateur page 26

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2.2
It displays the voltage on the module for channel B (V
0.B
the animation of the current of the PV module. At the beginning of this view there is a temporarily reference to the visualized
channel: in this case "c b" " i.e. the size concerning channel B.
3.0
It displays the total charge current of both channels (P
A.B
the animation of the charging current. At the beginning of this view there is a temporarily reference to the visualized
channels: in this case "cAb" i.e. the size concerning both channels A+B.
3.1
It displays the power of the module of the channel A (P
A.0
animation of the current of the PV module. At the beginning of this view there is a temporarily reference to the visualized
channel: in this case "cA" i.e. the size concerning channel A.
3.2
It displays the power of the module of the channel B (P
0.B
animation of the current of the PV module. At the beginning of this view there is a temporarily reference to the visualized
channel: in this case "c b" i.e. the size concerning channel B.
4.0
It displays the counter of total recharged energy of both channels (E
A.B
with only the animation of the current in charge At the beginning of this view there is a temporarily reference to the
visualized channel: in this case "cAb" i.e. the size concerning both channels A+B.
4.1
It displays the counter of the energy supplied from the module of channel A (E
A.0
remain with only the animation of the current of the PV module. At the beginning of this view there is a temporarily
reference to the visualized channel: in this case "cA" At the beginning of this view there is a temporarily reference to the
visualized channel: in this case A.
4.2
It displays the counter of the energy supplied from the module of channel B (E
0.B
remain with only the animation of the current of the PV module. At the beginning of this view there is a temporarily
reference to the visualized channel: in this case "c b" At the beginning of this view there is a temporarily reference to the
visualized channel: in this case B.
5.0 It displays the battery temperature detected by the external sensor (T
except for animations. A flash of the battery icon and of "°C" symbol indicates the absence of remote temperature sensor
6.0 It displays the temperature detected by the sensor that is inside WRM30 (T
load status and low battery alarm. From this temperature depends the derating as in the typical curve in Graph 3 and the
Overtemperature protection.
7.0 It displays the current absorbed by the load (I
of the load current.
8.0 It displays the power absorbed by the load (P
of the load current.
9.0 It displays the counter of energy absorbed by the load (E
animation of the load current.
- Pressing and holding for 1 sec
Others
- If you do not press any button for 2 minutes, you go back automatically to the main page from any other page. This is also
true in the environment of Configuration (see next paragraph).
Animations on the first page appear in the following cases the animation "panel current" only if it is day, the animation "charging current" only if the charge is on,
1
the animation "Load current" only if the output is on.
2
This information is also shown on the first page but with a lower frequency of flashing.
3
The current and power of the module for each channel (I
Navigation menu scheme
WRM30+
User manual
). Other indications remain the same of the main page with only
chB
P
chA+
chB
). The other indications of the main page remain with only the
chA
). The other indications of the main page remain with only the
chB
). The other indications of the main page remain with only the animation
LOAD
). The other indications of the main page remain with only the animation
LOAD
). The other indications of the main page remain with only the
LOAD
button, you return to the main page from any page.
P
) are not directly measured but they are recalculated internally.
chX,
chX
8
). The other indications of the main page remain with only
). The other indications of the main page remain
chA+EchB
). The other indications of the main page
chA
). The other indications of the main page
chB
). The other indications of the main page remain,
BAT
). Remain indications of the icons day/night,
INT
EN
2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

321532Phs-321532

Table des Matières