Ferroli EGEA 90 LT Manuel D'utilisation, Installation Et Entretien page 144

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Parame-
Description
ters
Type of evaporator fan (EC; AC; AC with double
P14
speed; EC with dynamic speed control)
Type of safety flow switch for hot / solar water re-
P15
circulation circuit, low pressure selection switch
P16
Solar mode integration
Heat-pump starting delay after DIG1 opening in
P17
solar mode= 1 (with DIG1)
Lower water probe temperature value to stop
P18
the heat-pump in solar mode integration = 1
(working with DIG1)
Hysteresis on lower water probe to start the
P19
pump in solar mode integration = 2 (direct con-
trol of thermal solar system solar)
Temperature threshold for solar drain valve / so-
lar collector roll-up shutter action in solar mode
P20
integration = 2 (direct control of thermal solar
system solar)
Lower water probe temperature value to stop
P21
the heat-pump in photovoltaic mode integration
Upper water probe temperature value to stop
P22
the electrical heater in photovoltaic mode inte-
gration
P23
Photovoltaic mode integration
P24
Off-peak working mode
P25
Offset value on upper water temp probe
P26
Offset value on lower water temp probe
P27
Offset value on air-inlet temp probe
P28
Offset value on defrosting temp probe
P29
Antilegionella starting hour
Hysteresis on upper water probe for electrical
P30
heater working
Heat-pump working period in AUTO mode for
P31
heating rate calculation
Temperature threshold for electrical heater us-
P32
age in AUTO mode
144
EN
Range
0 = EC
1 = AC
2 = AC with double speed
3 = EC with dynamic speed
control
0 = NC
1 = NO
2 = low pressure selection
switch
0 = exclusive function
1 = working with DIG1
2 = Direct control of thermal
solar system
10÷60 min
20÷60°C
5÷20°C
100÷150°C
30÷70°C
30÷80°C
0 = exclusive function
1 = activated
0 = exclusive function
1 = activated with ECO
2 = activated with AUTO
-25÷25°C
-25÷25°C
-25÷25°C
-25÷25°C
0÷23 hours
2÷20°C
10÷80 min
0÷20°C
cod. 3541T580 - Rev. 06 - 04/2022
EGEA
Default
0
0
0
20 min
40°C
10°C
140°C
62°C
75°C
0
0
0°C
0°C
0°C
0°C
23 hours
7°C
30 min
4°C
90 LT - 120 LT
Notes
Modifiable
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Egea 120 lt

Table des Matières