English
"Read" menu
This menu allows you to read some the operating
parameters of the appliance
With the controller "ON", press "M" and ON/
OFF simultaneously for 3 seconds.
Select the "rEAd" menu using the TOUCH
PAD and confirm with "Enter".
Select the parameter to be read using the
TOUCH PAD. Once you have selected the
parameter, the value will appear on the di-
splay.
Press the "M" button once to return to parameter
selection; to exit the menu, press the "M"
button 3 times.
T1
value of external air temperature probe T1
T2
value of intake air temperature probe T2
value of stale extracted air temperature
T3
probe T3
value of disposed air temperature probe
T4
T4
CO2
value of CO
RD1
Fan voltage
RD2
fan speed
Number of operating hours of the appliance
Cnt
(fan hours rpm > 0)
Configuration of power board dip switch
DIP
DESCRIPTION
detected
2
Return air
Supply air
V
Return air
Supply air
Dip n°
186
T1
°C
T2
°C
°C
T3
°C
T4
V
1234
5678
=
=