Napoleon GT8N Instructions D'installation Et D'opération page 41

Gaz naturel/ propane
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SYMPTOM
No gas to the
Switch is defective.
main burner;
switch is on.
Burner orifi ce is blocked.
Control valve faulty.
Faulty valve.
Burner will not
No gas at the burner.
light, ignitor
sparks.
Out of propane gas.
Ignitor will not
No spark at ignitor.
SENSOR
spark.
ELECTRODE
1 /8"
3.2mm
GAP
CERAMIC
HIGH
BODY
VOLTAGE
IGNITION
CABLE
Spark gap is incorrect.
Remote wall
Wall switch is mounted
switch is in "OFF"
upside down.
position; burner
Remote wall switch is
comes on.
grounding.
Remote wall switch wire
is grounding.
Faulty wire.
Pilot is not
Pilot has been painted
functioning
properly.
PROBLEM
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TEST SOLUTION
Connect a jumper wire across the wall switch
terminals; if main burner lights, replace switch /
thermostat.
Remove stoppage in orifi ce.
Replace.
Replace.
Check that the manual valve is turned on.
Replace the valve.
Fill the tank.
Check the power source. (ie. fuse, circuit breaker)
Check that the wire is connected to both the ignitor
and the control module.
Check that the spark is not jumping to ignitor cover.
Replace the wire if the wire insulation is broken or
frayed.
Replace the electrode if the ceramic insulator is
cracked or broken.
Spark gap should be 0.125" (3.2mm) from the
electrode tip to the sensor tip.
Reverse.
Replace.
Check for ground (short); repair ground or replace
wire.
Replace.
Using a piece of sandpaper or emery cloth remove
the paint from the pilot hood, ignitor and fl ame sensor.
41
42.6_2B
W415-1367 / 12.05.14
EN