Fault Indications On The Display - Valeo CITYSPHERE Notice D'utilisation

Masquer les pouces Voir aussi pour CITYSPHERE:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.3. Fault indications on the display

Fault
indica-
Description
tion
Defective inside
air temperature
sensor
Defective outside
air temperature
sensor
Alternator voltage
below 19.5 V
Alternator voltage
below 10 V
Roof Top Air Conditioning System Citysphere
System behavior
• At outside temperatures above 22°C
the air conditioning system runs at the
lowest power level. The fan speed lev-
el can be changed manually.
• At outside temperatures below 22°C
the air conditioning system does not
operate.
• The cooling function is blocked.
• At inside temperatures above 22°C the
fun speed is at the lowest level (manu-
ally changeable).
Cooling and heating functions are
blocked.
Cooling and heating functions are
blocked.
Remedy
• Check the inside temperature sensor
or the wiring
• Contact an authorized service point
• Check the outside temperature sen-
sor or the wiring
• Contact an authorized service point
• Start engine
• Contact an authorized service point
of the vehicle manufacturer
• Start engine
• Contact an authorized service point
of the vehicle manufacturer