3. User interface

A.
LED color meaning
On the product, there are 2 Led indicators (1) and (2).
-
(1):
o Red fix:
o Blue fix:
o Red/Blue blink:
-
(2):
o Red fix:
o Blue fix:
o Green fix:
o Green flash:
o Green blink:
B.
Buttons
There is a button (3) at the right side of the product.
It is used to go into RF Link mode, to do this:
o Press it for 5 seconds
o Led (2) turns Green fix
o Now product is ready for a RF link with BT-M6Z02-RF
Note: if product is in RF link mode and you press it 5 seconds again, product is reset: the RF link is removed.
C.

DIP switch configuration

When you unscrew the front face of BT-HCM02-RF, on the right of the product, you have access to 4 switches
used for advanced configuration:
By default position is OFF for the 4 switches
Switch 1: Heat / Cool (HC) signal source (refer to section 7)
ON:
BT-M6Z02-RF gets HC information from the BT-CT02-RF
OFF : BT-M6Z02-RF gets HC information from the inputs (Water sensor OR Input free contact)
Switch 2: Humidity function
ON:
Function is OFF (dehumidifier output not active)
OFF: Function is ON: when a humidity default is detected in the system dehumidifier output is ON
Switch 3: Time before switching Heat / Cool (HC) mode
ON:
HC Switch is effective 2 seconds after the change has been detected
OFF: HC Switch is effective 5 minutes after the change has been detected
Switch 4: Type of control on the heating and cooling outputs
ON:
Heating or cooling outputs follow the heating or cooling demand of the installation (Ex: In heating
mode, if any zones are in heating demand, the heating is switched ON)
OFF: Heating or cooling outputs follow the working mode of the installation (Ex: In heating mode, the
heating output is always ON)
Pump is activated
Dehumidifier is activated (humidity funtion activated and default detected)
Pump and Dehumidifier are activated
system in heating
system in cooling
your system is in RF Link mode (waiting for RF link of BT-M6Z02-RF)
BT-HCM02-RF has received a RF frame from the BT-M6Z02-RF
RF error or BT-HCM02-RF not linked