Economy Setting; Programming; Quick Programming - Elesta RTU200B Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cool mode:
The thermostat does not control the heat pump,
the Frost Protection request shuts down the system.
Manually switch the thermostat and heat pump to
Heat mode.
Turn the knob to exit the setting mode.

Economy setting (

Turn the knob to
:
Heat mode: setting from 10°C to 30°C (16°C by default)
Cool mode: setting from 18°C to 35°C (28°C by default)
Press + or - to make your choice.
Turn the knob to exit the setting mode.
The setting of the Economy set-point in Cool mode
can only be accessed if CF05=1, see "Starting up"
menu. If CF05=0, the screen displays "- - - -".
Comfort setting (
Turn the knob to
:
Heat mode: setting from 10°C to 30°C (20°C by default)
Cool mode: setting from 18°C to 35°C (24°C by default)
Press + or - to make your choice.
Turn the knob to exit the setting mode.
)
)
- 30 -

Programming

When starting up, the "Comfort mode from 6am
to 11pm" program is applied to all the days of the week.
To change the programming, turn the knob to PROG.
The 1
st
time slot flashes on and off.
Time slot
Ex :
consulted
Heat mode
1
st
time
slot
Economy mode
for 1 hour
Confirm and go to
Comfort
the next day
for 1 hour
At the end of the Heat mode programming, you
access the Cold mode programming.

Quick programming:

To apply the same program to the following day, press
and hold the OK button for approximately 3 seconds
until the program of the following day is displayed.
Turn the knob to exit the programming mode.
Day
Program
profile
Go to the next
program change
- 31 -