Electrical safety:

Caution: to avoid accidents and
injuries from electric shocks:
• The equipment is not to be operated if
there are people in the water. There is
a risk of electric shock.
• After erection, the mains plug must be
freely accessible when the equipment is
in operation.
• Before operating your new pump, have
a specialist check:
- The earthing, the protective multiple
earthing; the residual current circuit
breaking must be compliant with the
safety regulations of the energy supply
company and function without fault,
- The protection of the electrical plug
connections from the wet.
- If there is a risk of flooding, fix the
plug connections in an area that is
safe from flooding.
• Ensure that the mains voltage matches
the specifications on the rating plate.
• The electrical installation shall be ac-
cording to national wiring rules.
• Connect the equipment only to a socket
with a residual current protection de-
vice (residual current circuit breaker)
with a rated current of not more than
30 mA; minimum fuse 6 amperes.
• Before each use, check the equipment,
cable and plug for damage. Defec-
tive cables are not to be repaired, but
rather replaced by new ones. Have
damage on your equipment repaired
by an authorised specialist.
• If the power cable for this equipment is
damaged, it must be replaced by the
manufacturer, a customer service agent
of the same or a similarly qualified per-
son in order to prevent hazards.
• Do not pull the plug from the socket by
44
the cable. Protect the cable from heat,
oil and sharp edges.
• Do not carry or fix the equipment by
the cable.
• Use only extension cables that are pro-
tected from spray water and designed
for outdoor use. Always fully unroll a
cable drum before use. Check the ca-
ble for damage.
• Disconnect the mains plug from the sock-
et before all work on the equipment, in
case of leaks in the water system, during
work breaks, and when not in use.
• The cross-section of mains connection
lines must be no smaller than rubber
hose lines with the designation H07RN-F.
The line must be 10 m long.
The flexible lead cross-section of the ex-
tension cord must at least 2.5 mm
• Protect cables and electrical connections
against moisture. Make sure that cables
and electrical connections are located in
areas safe from flooding.

Putting into service

Assembling instructions

Before installing the aluminium
tubes and the flexible tube, check
that a sealing ring has been in-
serted in each screw socket. If not,
insert the sealing ring in the follow-
ing manner:
Inserting the sealing rings:
1. Press:
- One small sealing ring (23) into
each of the threaded sleeves
in the three aluminium tubes.
(13/14/15),
- One large sealing ring (21)
into the threaded sleeve on the
flexible tube (20).
.
2