pressed when the mains switch is turned on in order to re-start theWFE 10.
To change filters, the tension locks (9) between the vacuum casing (15) and the filter
casing (13) are opened and the vacuum casing lifted out. Following this, the expanded
metal condensation filter and the fine particulate air filter can be taken out of the filter
casing. The submicron particulate air filter and the wide band filter can subsequently
be lifted out by the brackets.
Warning: When inserting filters take care to follow the correct sequence and fit
them in the correct position.
The dirty filters must be treated as hazardous waste and must be disposed of in
accordance with Waste Code 31 435 or local regulations.
Maintenance diagram - see page 50

3. Operating instructions

The expanded metal condensation filter can be washed out with alcohol and subsequently
re-used. When doing so, take care that it is replaced in the correct position. Coarse
mesh upwards. The fine particulate air filter, submicron particulate air filter and wide
band gas filter are not re-usable.
- The fine particulate air filter is the preliminary filter of the submicron particulate air
filter and therefore has to be changed more frequently.
- The submicron particulate air filter is homologated Class S in accordance with DIN
24 184.
- The wide band gas filter is ideally suited to the cleaning of gas fumes and consists of
50% activated carbon and 50% Purafil. The effect of the wide band gas filter is not
recorded by the differential pressure measurement device. It must therefore be checked
at regular intervals by the user for gas punctures.
The wide band gas filter is also available with a pure activated carbon filling for extracting
adhesive vapours. In this application it is recommended that you also replace the
submicron particulate air filter by an activated carbon filter.
A high concentration of noxious gas leads to warming of the activated carbon. Allow
the unit to run on without admitting noxious gas.
WFE10
21
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
Warning: the WELLER WFE 10 is not suitable for the extraction of flammable gases.
For diverting the outgoing air, instead of the air exit diaphragm a flange for a DIN 100
breather tube can be fitted. The breather tube is simply stuck onto the flange. No addi-
tional seal is required.
For diagram - see page 51

4. Safety instructions

The manufacturer accepts no liability for other usage that differs from the operating
instructions, nor for any unauthorised modifications.
These operating instructions and the warning instructions they contain should be read
carefully and kept in a clearly visible place adjacent to the soldering unit. Failure to
adhere to warning instructions could cause accidents and injuries or be detrimental to
health.
WELLER's WFE 10 soldering fume extraction device complies with the EC certificate of
conformity in accordance with the basic safety standards of EC guidelines 89/336/EEC,
73/23/EEC and 89/392/EEC.

5. Accessories

5 36 342 99 Expanded metal condensation filter 260 x 260 x 15mm
5 36 339 99 Fine particulate air filter DIN 24184, 260 x 260 x 12mm (10 Stück)
5 36 355 99 Fine particulate air filter EU 7 (10 Stück)
5 36 340 99 Submicron particulate air filter Class S, DIN 241184, 305 x 305 x 90mm
5 36 341 99 Wide band gas filter, 50% activated carbon, 50% Purafil
5 36 354 99 Activated carbon filter
5 36 346 99 Exhaust flange for DN100 Tube
5 26 162 99 FE80 Temtronic soldering pencil with fume extraction device antist., 80W
5 25 153 99 FE50 Temtronic soldering pencil with fume extraction device antist., 50W
5 32 152 99 FE50M Magnastat soldering pencil with fume extraction device, 50W
5 29 106 99 FE25 Micro soldering pencil with fume extraction device, 25W
5 29 162 99 WSP 80 FE Soldering pencil with fume extraction device antistatic, 80 W
5 29 166 99 FE 75 Soldering pencil with fume extraction device antistatic, 80 W